18
tqna49e1 (2010-05)
n If no sensor cable is available, make one according to the
following diagram.
15
8
9
1
D-Sub,15-pin
female
soldering
side
Electrical connection
Pin 1, 4 Relay SP1, closing contact
Pin 2 Signal Output
or thresholds SP1/2
Pin 5 Supply common, GND
Pin 7, 11 Supply
Pin 8, 9 Relay SP2, closing contact
Pin 10 Gauge identification
Pin 12 Signal common
Pin 13 RS232, TxD
Pin 14 RS232, RxD
Pin 15 Housing (Chassis Ground)
case Connector case
case
Gauge with switching functions
4
1
8
9
10
Ident
13
14
2
TxD
RxD
12
7
11
5
1 MΩ
15
100nF
18 V
10
Ω
o Connect the sensor cable to the gauge and secure it using
the lock screws.
p Connect the sensor cable to the controller.