Installation and User Manual ADPRO FastTrace-R by Xtralis
44 Doc 13972_03
A single 9-way D connector is provided on the unit to support RS422 and RS485 connectivity to
PTZ camera stations. The connectivity is shown below. To change between RS422 and RS485,
use DIP switch 5 on the rear of the unit. To provide termination of the RS485 line use DIP switch
8 on the rear of the unit.
Figure 47: Pin Numbering of the PTZ Port
Table 8: PTZ Port Connections
Figure 48: Typical RS485 Connection to Multiple Telemetry Stations
Name Pin Description
TXD+ 2 RS422(+) / RS485 (+)
TXD- 3 RS422 (-) / RS485 (-)
GND 5 Signal Ground
RXD+ 6 RS422 (+)
RXD- 7 RS422 (-)