AVE MV DR4000 Manual de instrucciones Pagina 11

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 87
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 10
9
2.3 ALARM In/Out
ALARM1 IN ALARM4 IN
ALARM2 IN ALARM3 IN
ALARM OUT
RECORD IN GROUND
DISK FULL
ALARM RESET
12345
6789
THIS FIGURE IS LOOKED FROM THE REAR VIEW
1. GND: Ground Contact.
2. ALARM OUT (OUTPUT): This is a common alarm output trigger. Connect this to external
devices such as buzzers or lights. Switches Low (GND) (
5V
0V(Active)
)
3. DISK FULL (OUTPUT): This is a disk full output trigger. Connect this to external devices such
as buzzers or lights. Switches Low (GND) (
5V
0V(Active)
)
4. ALARM RESET (INPUT): This pin connects to an alarm-clear device for clearing an alarm. Use
a Normally Open switch to GND. (
5V
0V(Active)
)
5. RECORD IN (INPUT): This pin connects to a record trigger device for starting a record.
Negative Trigger. (
5V
0V(Active)
)
6. ALARM4 IN (INPUT): This is an alarm input (for CH 4 ), which can be programmed in the menu
system to Normally Open or Normally Closed operation.
7. ALARM3 IN (INPUT): same as the above, for CH 3
8. ALARM2 IN (INPUT): same as the above, for CH 2
9. ALARM1 IN (INPUT): same as the above, for CH 1
Vista de pagina 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 86 87

Comentarios a estos manuales

Sin comentarios